Shelf-life and stability studies

Products are held at defined temperature and humidity and tested at scheduled time points for the attributes that limit their shelf life. Developers order a study to set or support a shelf life, a storage statement or a choice of packaging.

Tests in this category

Shelf-life and stability studies: tests
SelectNo.TestTechniqueReported as
6.1Food and nutritional productsReal-time and accelerated storageResult for each attribute and time point
6.2Pharmaceutical and nutraceutical productsLong-term and accelerated storageResults by batch, condition and time point
6.3Agricultural productsStorage with time-point testingResult for each attribute and time point
6.4Viability of microbial formulationsViable count over storage timeCFU/g or CFU/mL and log10 CFU
6.5Stability under different storage conditionsStorage at several conditionsResults by condition, pack and time point

Reference basis is the published method a procedure is built on. The method used, and any modification, is stated on the report. Sample amount, turnaround and price are confirmed on the quote.

Overview

A stability study is run to a written protocol. The protocol fixes the storage conditions, the time points, the attributes tested at each time point, the acceptance criteria and the way the data are evaluated. The client supplies the acceptance criteria, normally the product specification. We store the samples under the stated conditions, pull them on schedule and test them.

The tests at each pull come from our other five categories: assay of an active or marker compound by UPLC-PDA, volatile compounds by GC-FID/MS, moisture and pH, microbial counts, and the viable count of a declared organism. The same method is used at every time point, so the results of one study are comparable from the first pull to the last.

Two kinds of storage are used. Real-time storage, called long-term storage in pharmaceutical guidelines, holds the product at its intended storage condition for the period under study. Accelerated storage holds it at a higher temperature, usually with higher humidity, so that changes appear sooner. Accelerated data estimate a shelf life and show which attribute changes first. Real-time data confirm it.

The report lists every result by condition and time point beside the initial value and the acceptance criterion. We run these as development and supporting studies. Results relate to the lots, packs and conditions tested. The client decides the shelf life and the storage statement from the data.

Fig. 1Pull schedule for a 24-month study on the general-case storage conditions of ICH Q1A(R2). Filled marks are scheduled pulls. Open marks are intermediate-condition samples, tested only if the accelerated condition shows a significant change. Illustrative data.
Time (months)0369121824Storage conditionLong-term25 °C ± 2 °C / 60 % RH ± 5 % RHIntermediate30 °C ± 2 °C / 65 % RH ± 5 % RHAccelerated40 °C ± 2 °C / 75 % RH ± 5 % RHOne initial test for all conditionsFilled: scheduled pull.Open: tested only after a significant change at the accelerated condition.Time (months)0369121824Long-term25 °C ± 2 °C / 60 % RH ± 5 % RHIntermediate30 °C ± 2 °C / 65 % RH ± 5 % RHAccelerated40 °C ± 2 °C / 75 % RH ± 5 % RHOne initial test for all conditionsFilled: scheduled pull.Open: tested only after a significant changeat the accelerated condition.

General case of ICH Q1A(R2) for a product stored at room temperature, with 25 °C / 60 % RH as the long-term condition. Where 30 °C / 65 % RH is the long-term condition there is no intermediate condition. The attributes tested at each pull are set in the protocol.

6.1 Shelf-life and stability evaluation of food and nutritional products

Technique
Real-time and accelerated storage
Principle
Packed product from one lot is stored at its labeled storage condition (real time) and, where the protocol includes it, at a higher temperature (accelerated). Units are pulled at the scheduled time points and tested for the attributes that limit shelf life for that product, usually moisture, pH, microbial counts and the content of a declared nutrient or active. Each result is compared with the time-zero value and the client's acceptance criterion. The attribute that first reaches its criterion limits the shelf life.
Determined
  • Moisture content
  • pH
  • Total viable count; yeast and mold count
  • Coliforms, Escherichia coli and Salmonella, where the specification includes them
  • Declared nutrient or active: vitamins, bioactive or marker compounds (UPLC-PDA)
  • Volatile compounds (GC-FID/MS), where loss of aroma or an off-odor compound is followed
Reported as
Result for each attribute at each condition and time point, in the units of the test, beside the time-zero value and the client's acceptance criterion
Controls
  • Time-zero testing of the same lot before storage
  • Same method and sample preparation at every time point
  • Batch controls of each test at every pull (blank, calibration, check standard, control organism)
  • Storage conditions monitored and recorded for the whole study
  • Pull dates recorded against the schedule; deviations stated on the report
  • Product stored in the pack named in the protocol
Sample condition
Supply units from one lot in the final sealed pack, labeled with the lot number and the storage statement. Ship at the labeled storage condition. The number of units is confirmed on the quote.
Reading the result
An accelerated result is an estimate, and it holds only if the same change limits shelf life at the higher temperature and at the storage temperature; real-time data confirm the shelf life. There is no single mandatory international protocol for foods, so the conditions, time points and attributes are agreed for each product.
Reference basis
  • IFST (1993)Shelf Life of Foods: Guidelines for its Determination and Prediction
  • Labuza and Schmidl, Food Technology 39, 57 (1985)Accelerated shelf-life testing of foods
  • ICH Q1A(R2)Stability Testing of New Drug Substances and Products
Product areas
  • Food and nutritionalDietary supplement powders, capsules and tablets; Protein and meal-replacement powders; Functional beverages and drink mixes; Mushroom and botanical powders and extracts; Dried foods, cereals and snack products; Fermented foods and foods with live cultures

6.2 Stability studies of pharmaceutical and nutraceutical products

Technique
Long-term and accelerated storage at ICH conditions
Principle
Samples in the proposed container closure system are stored at the ICH Q1A(R2) long-term (25 °C / 60 % RH or 30 °C / 65 % RH) and accelerated (40 °C / 75 % RH) conditions. Long-term samples are tested every 3 months in the first year, every 6 months in the second and annually thereafter; accelerated samples at three or more time points over 6 months. Significant change at the accelerated condition leads to intermediate testing at 30 °C / 65 % RH, unless that is the long-term condition.
Determined
  • Assay of the active ingredient or marker compound (UPLC-PDA)
  • Chromatographic profile: new or growing peaks beside the active
  • Moisture content
  • pH of liquids and reconstituted products
  • Total viable count; yeast and mold count
  • Escherichia coli and Salmonella, where the specification includes them
Reported as
Results by batch, condition and time point beside the initial value and the client's specification; assay also as percent of initial, for comparison with the ICH Q1A(R2) definition of significant change
Controls
  • Time-zero results for each batch before storage
  • Stability-indicating assay: shown to separate the active from its degradation products before the study starts
  • System suitability, calibration and check standard in every analytical run
  • Storage temperature and humidity monitored and recorded against the ICH Q1A(R2) tolerances (±2 °C, ±5 % RH)
  • Excursions beyond tolerance for more than 24 hours described on the report
  • Pull date and test date recorded for every time point
Sample condition
Supply each batch in the proposed container closure system, sealed and labeled with the batch number and date of manufacture. Send the specification with the request. Quantities are confirmed on the quote.
Reading the result
ICH Q1A(R2) is written for the registration of new drug substances and products; for nutraceuticals and development batches its conditions and time points are adopted by protocol, and we run these as development and supporting studies. The attributes followed are those in our test catalog, which does not include dissolution or disintegration.
Reference basis
  • ICH Q1A(R2)Stability Testing of New Drug Substances and Products
  • ICH Q1EEvaluation for Stability Data
  • WHO Technical Report Series No. 1010, Annex 10 (2018)Stability testing of active pharmaceutical ingredients and finished pharmaceutical products
Product areas
  • Pharmaceutical-relatedNutraceutical capsules, tablets and softgels; Nutraceutical powders and sachets; Oral liquids, tinctures and syrups; Standardized botanical and mushroom extracts; Development batches of pharmaceutical-related formulations; Active ingredients and excipients held as raw materials
Fig. 2Erinacine A content of one lot stored at the long-term condition (25 °C / 60 % RH, 12 months) and at the accelerated condition (40 °C / 75 % RH, 6 months), with an example specification of not less than 18.0 mg/g. Simulated study. Illustrative data.
17.518.018.519.019.520.020.5Erinacine A (mg/g, dry-weight basis)036912Time (months)Long-term, 25 °C / 60 % RH19.5 mg/g, 97.5 % of initialAccelerated, 40 °C / 75 % RH18.5 mg/g, 92.5 % of initial5 % below initial: 19.0 mg/gExample specification: not less than 18.0 mg/g17.518.018.519.019.520.020.5Erinacine A (mg/g, dry-weight basis)036912Time (months)Long-term, 25 °C / 60 % RH19.5 mg/g, 97.5 % of initial5 % below initial: 19.0 mg/gExample specification: not less than 18.0 mg/gAccelerated,40 °C / 75 % RH18.5 mg/g,92.5 % of initial
  • Long-term, 12 months: 19.5 mg/g, loss 2.5 %
  • Accelerated, 6 months: 18.5 mg/g, loss 7.5 %: significant change
  • Example specification, not less than 18.0 mg/g: met at every time point

For a drug product, ICH Q1A(R2) defines a 5 % change in assay from the initial value as a significant change. The accelerated series loses 7.5 % in 6 months; in a protocol that follows the guideline, this leads to testing at the intermediate condition, 30 °C / 65 % RH. The long-term series loses 2.5 % in 12 months. That change, 0.5 mg/g, is smaller than the expanded uncertainty of a single result in the worked example on this site (±0.8 mg/g, k = 2), so it is read as a trend across five time points and not as a difference between two results.

6.3 Shelf-life and stability testing of agricultural products

Technique
Protocol-defined storage with time-point testing
Principle
Agricultural products here are commodities and inputs: dried plant materials, feed ingredients, plant extracts, biostimulants and microbial inoculants. The material is stored in its commercial pack at the condition on its label or data sheet and, where the protocol includes it, at a warmer or more humid condition. At each pull we test the physicochemical, microbiological and active-ingredient attributes named in the protocol. Moisture uptake, loss of a marker compound, microbial growth and loss of viable count are the usual limiting changes.
Determined
  • Moisture content and pH; bulk density and solubility where they are specified
  • Marker or active compound content (UPLC-PDA); chromatographic fingerprint of plant extracts
  • Volatile compounds (GC-FID/MS), where aroma or volatile content is followed
  • Total viable count; yeast and mold count
  • Mycotoxins, where mold growth during storage is a concern
  • Viable count of the declared organism in microbial inoculants and microbial biostimulants
Reported as
Result for each attribute at each condition and time point, in the units of the test, beside the initial value and the client's acceptance criterion; change from initial
Controls
  • Time-zero testing of the same lot before storage
  • Same method and sample preparation at every time point
  • Batch controls of each test at every pull
  • Storage temperature and humidity monitored and recorded
  • Material stored in its commercial pack or in the same packaging material
  • Sub-sampling of bulk material recorded at each pull
Sample condition
Supply material from one lot in its commercial pack, sealed, with the lot number and the storage statement from the label or data sheet. Ship live microbial products at their labeled temperature.
Reading the result
No single published protocol covers the stability of agricultural commodities and inputs, so the conditions, time points and attributes are those of the protocol agreed with the client. Results relate to the lot and pack tested.
Reference basis
  • ICH Q1A(R2)Stability Testing of New Drug Substances and Products
  • EMA/HMPC/CHMP/CVMP/201116/2005 Rev. 3Guideline on quality of herbal medicinal products/traditional herbal medicinal products
Product areas
  • AgriculturalDried plant materials and botanical powders; Plant and mushroom extracts; Feed ingredients and feed additives; Biostimulants, liquid and dry; Microbial inoculants and biofertilizers

6.4 Microbial viability and stability assessment of microbial formulations

Technique
Viable count over storage time
Principle
The formulation is stored in its final pack at the stated conditions. At each time point a weighed portion is rehydrated or suspended in diluent, diluted in tenfold steps and plated on the medium suited to the declared organism. Plates are incubated at the temperature and atmosphere the organism requires, and colonies are counted on plates in the countable range. We calculate CFU/g or CFU/mL and its log10 value. The log reduction is the initial log10 count minus the log10 count at that time point.
Determined
  • Viable count of the declared organism or group, for example lactic acid bacteria, bifidobacteria, spore-forming Bacillus, yeasts, or inoculant bacteria and fungi; the counting method is agreed before the study
  • Log reduction from the initial count at each time point
  • Contaminant indicators where the specification includes them: yeast and mold count, coliforms
  • Moisture content of dry formulations, where the protocol includes it
Reported as
CFU/g or CFU/mL and log10 CFU at each condition and time point; log reduction from the initial count; comparison with the label claim or specification the client supplies
Controls
  • Time-zero count of the same lot before storage
  • Same rehydration step, diluent, medium and incubation at every time point
  • Counts taken from consecutive dilutions within the countable range
  • Uninoculated diluent and medium plated as sterility controls
  • Reference strain plated to show that each batch of medium supports growth
  • Colony morphology checked against the declared organism; identity confirmed by molecular identification on request
Sample condition
Ship in the final sealed pack at the labeled storage temperature, chilled where the label requires it. State the declared organism, the label claim and the plating medium the manufacturer recommends, if any.
Reading the result
A plate count measures the cells that form colonies under the chosen conditions, so the result depends on the rehydration step, the medium and the incubation, and cells that are alive but do not grow on the plate are not counted. In a product with several strains, each strain is counted separately only where a medium or an incubation condition separates it.
Reference basis
  • ISO 7218:2024Microbiology of the food chain — General requirements and guidance for microbiological examinations
  • USP <64>Probiotic Tests
  • ISO 15214:1998Microbiology of food and animal feeding stuffs — Horizontal method for the enumeration of mesophilic lactic acid bacteria — Colony-count technique at 30 °C
  • ISO 29981:2024Milk products — Enumeration of bifidobacteria — Colony-count technique
Product areas
  • Food and nutritionalProbiotic powders, capsules and sachets; Fermented foods and beverages with live cultures; Starter cultures for fermented foods; Brewing and baking yeasts
  • AgriculturalMicrobial inoculants and biofertilizers; Microbial biostimulants; Silage inoculants; Live microbial feed additives
  • Pharmaceutical-relatedProbiotic nutraceutical products; Freeze-dried culture concentrates; Microbial strains held as production stocks
Fig. 3Viable count of one lot of a freeze-dried lactic acid bacteria formulation stored at 5 °C and at 25 °C / 60 % RH for 12 months, with an example label claim of 1 × 108 CFU/g. Simulated study. Illustrative data.
7.58.08.59.09.5Viable count (log10 CFU/g)036912Time (months)Refrigerated, 5 °C8.90, log reduction 0.10Ambient, 25 °C / 60 % RH7.80, log reduction 1.20Example label claim: not less than 1 × 108 CFU/g (8.0 log10 CFU/g)7.58.08.59.09.5Viable count (log10 CFU/g)036912Time (months)Refrigerated, 5 °C8.90, log reduction 0.10Ambient, 25 °C / 60 % RH7.80, log reduction 1.20Example label claim:not less than 1 × 108 CFU/g(8.0 log10 CFU/g)

At 5 °C the count falls by 0.10 log10 in 12 months, a change within the usual variability of a plate count. At 25 °C it falls by 1.20 log10, to 6.3 % of the initial count, and passes below the example label claim between the 9-month and 12-month pulls.

6.5 Evaluation of physicochemical, microbiological and active-ingredient stability under different storage conditions

Technique
Parallel storage at several conditions
Principle
One lot is divided between two or more storage conditions and, where packaging is compared, between two or more packs. All arms share one time-zero result and one pull schedule. At each pull we run the combined panel: physicochemical tests, microbiological tests and the assay of the active ingredient. Conditions are chosen from the label storage statement, the climatic zone of the intended market and the cold chain the product passes through. Storage temperature and, where it is controlled, humidity are monitored and recorded throughout.
Determined
  • Physicochemical: moisture content and pH; bulk density and solubility where they are specified
  • Microbiological: total viable count, yeast and mold count; viable count of a declared organism
  • Active ingredient: assay of the active or marker compound (UPLC-PDA); volatile compounds (GC-FID/MS)
  • Change from the initial value for each attribute in each arm
Reported as
Table of results by condition, pack and time point, with the change from initial and the client's acceptance criterion
Controls
  • One lot and one time-zero result shared by all arms
  • All arms pulled on the same dates and tested in the same run where the test allows
  • Storage temperature, and humidity where it is controlled, monitored and recorded for each condition
  • Excursions from the set tolerances stated on the report
  • Batch controls of each test at every pull
  • Pack material, closure and fill recorded for each arm
Sample condition
Supply one lot in each pack to be compared, sealed and labeled. State the label storage statement and the intended markets, so that the conditions can be chosen. Quantities are confirmed on the quote.
Reading the result
The comparison applies to the lot, the packs and the conditions tested. A condition outside the protocol, such as a temperature excursion during transport, is not covered by the result.
Reference basis
  • ICH Q1A(R2)Stability Testing of New Drug Substances and Products
  • WHO Technical Report Series No. 1010, Annex 10 (2018)Stability testing of active pharmaceutical ingredients and finished pharmaceutical products
  • ICH Q1DBracketing and Matrixing Designs for Stability Testing of New Drug Substances and Products
Product areas
  • Food and nutritionalSupplement powders in jars, pouches and sachets; Capsules and tablets in bottles and blisters; Drink mixes and beverage concentrates; Probiotic foods and supplements, chilled and ambient
  • AgriculturalDried plant materials in sacks and lined bags; Plant extracts in drums and pouches; Biostimulant liquids and powders; Microbial inoculants, chilled and ambient
  • Pharmaceutical-relatedNutraceutical products in alternative packs; Development formulations compared side by side; Extract ingredients in bulk and retail packs

Questions

Questions about shelf-life and stability studies
QuestionAnswer
Can an accelerated study replace a real-time study?No. Accelerated storage gives an early estimate and shows which attribute changes first. The estimate holds only if the same change limits shelf life at both temperatures. Real-time data at the labeled storage condition confirm the shelf life, so the two studies are normally started together on the same lot.
Who sets the acceptance criteria and the shelf life?The client. We test each attribute against the specification or limit the client supplies and report the time point at which any result falls outside it. The shelf life and the storage statement on the label are the client's decisions, based on the data.
How are the storage conditions chosen?From the storage statement on the label and the climate of the intended market. ICH Q1A(R2) gives 25 °C / 60 % RH or 30 °C / 65 % RH as long-term conditions and 40 °C / 75 % RH as the accelerated condition for products stored at room temperature. Chilled and frozen products are stored at their labeled temperature.
How many lots does a study need?ICH Q1A(R2) asks for at least three primary batches in a registration study for a medicine. A development or supporting study can run on one lot, and its results then relate to that lot. Including more lots shows whether the result holds from batch to batch.
Can a shelf life be extended beyond the last time point tested?For medicines stored at room temperature, ICH Q1E allows limited extrapolation when the accelerated condition shows no significant change: at most twice the period covered by long-term data and at most 12 months beyond it, with supporting data and, where the data change over time, a statistical analysis. Foods have no such rule; their shelf life rests on real-time data.