Specialized analytical testing

This category measures specific compounds and elements in a product by UPLC-PDA, GC-FID/MS and ICP-MS: metabolites and bioactive compounds, mycotoxins, vitamins, volatile compounds, residual solvents and heavy metals. Product developers order these tests to check label claims, ingredient specifications and contaminant levels.

Tests in this category

Specialized analytical testing: tests
SelectNo.TestTechniqueReported as
1.1Metabolites and bioactive compoundsUPLC-PDAmg/g or % w/w
1.2Mycotoxin analysisUPLC after clean-upµg/kg, as received
1.3Vitamin analysisUPLC-PDAmg/100 g or µg/100 g
1.4Volatile compoundsGC-FID/MSmg/kg or mg/L
1.5Residual solventsHeadspace GC-FID/MSmg/kg (ppm)
1.6Heavy metal analysisICP-MSmg/kg or µg/kg
Method development and validationUPLC-PDA, GC-FID/MS, ICP-MSValidation or verification report

Reference basis is the published method a procedure is built on. The method used, and any modification, is stated on the report. Sample amount, turnaround and price are confirmed on the quote.

Overview

The tests in this category identify and quantify individual compounds and elements in a sample. Three techniques are used: ultra-performance liquid chromatography with photodiode-array detection (UPLC-PDA), gas chromatography with flame-ionization and mass-spectrometric detection (GC-FID/MS), and inductively coupled plasma mass spectrometry (ICP-MS).

Liquid chromatography runs on a Waters ACQUITY UPLC H-Class Bio system with a PDA detector and is used for non-volatile compounds that absorb ultraviolet or visible light. Gas chromatography is used for compounds that are volatile and thermally stable enough to pass through a heated column; flame ionization gives the quantitative signal and mass spectrometry the identification. ICP-MS measures elements, not compounds, after the sample is digested in acid.

Every quantitative result is produced in the same sequence: a weighed test portion, a documented extraction or digestion, a calibration prepared from reference standards, and controls analyzed in the same batch. A concentration is reported only inside the calibrated range. A sample that reads above the range is diluted and measured again. The method used and the limit of quantitation are stated on the report; measurement uncertainty is reported on request, and whenever it affects a statement of conformity.

The worked example on this page is erinacine A in Hericium erinaceus mycelium, the laboratory's established method. The same sequence of identification, calibration and calculation applies to every compound quantified by UPLC-PDA. The example is a simulated run with illustrative data, not client data.

Fig. 1Erinacine A in a Hericium erinaceus mycelium extract by UPLC-PDA: the chromatogram at 340 nm and the peaks identified in it. Simulated run. Illustrative data, not client data.

1.1 Metabolites and bioactive compounds

Technique
UPLC-PDA
Principle
The sample is extracted with a solvent chosen for the analyte, clarified and diluted into the calibrated range. Compounds are separated by reversed-phase UPLC and detected by a photodiode array, which records a full absorbance spectrum at every point of the run. A peak is identified by its retention time against a reference standard and by its UV spectrum match. It is quantified at one wavelength against a multi-point external calibration, without extrapolation beyond the calibrated range.
Determined
  • Erinacine A in Hericium erinaceus mycelium (worked example)
  • Hericenones C and D
  • Other UV-absorbing compounds for which a reference standard is available, for example phenolic acids, flavonoids, alkaloids and curcuminoids
  • The compounds covered are confirmed on the quote
Reported as
mg/g or % w/w of each named compound, on an as-received or dry-weight basis; mg/L for liquids
Controls
  • Solvent blank and method blank
  • Multi-point calibration from a reference standard
  • System suitability: resolution, peak tailing and injection repeatability
  • Check standard within the run
  • Retention-time and UV-spectrum match for identification
  • Duplicate preparation or spiked sample where the method specifies one
Sample condition
Dry powders and extracts: sealed, protected from light and moisture. Fresh or wet material: chilled or frozen. State the target compound and, for extracts, the solvent or carrier.
Reading the result
A photodiode array detects only compounds that absorb ultraviolet or visible light; compounds without a chromophore, such as sugars, saturated lipids and many triterpenoids, need another detector or derivatization.
Reference basis
  • USP <621>Chromatography
  • ICH Q2(R2)Validation of Analytical Procedures
  • AOAC Official Methods of Analysis, Appendix KGuidelines for Dietary Supplements and Botanicals
Product areas
  • Food and nutritionalMushroom powders and extracts; Botanical powders and extracts; Functional beverages; Dietary supplement capsules and tablets; Fermented foods
  • AgriculturalMushroom mycelium and fruiting bodies; Dried herbs and plant material; Fermentation broths and microbial biomass; Crop and plant extracts
  • Pharmaceutical-relatedNutraceutical ingredients; Standardized botanical extracts; Finished capsules and tablets; Research and development formulations; Raw materials tested for a marker compound
Fig. 2Erinacine A, hericenone C and hericenone D: the three compounds of the laboratory’s established method.
Fig. 3Six-level external calibration for erinacine A at 340 nm. The sample peak area of 299.87 mAU·s reads as 24.00 µg/mL, inside the calibrated range of 1.00 to 50.00 µg/mL. Simulated run of a Hericium erinaceus mycelium extract, not client data. Illustrative data.
0100200300400500600700Peak area at 340 nm (mAU·s)Area = 12.48·c + 0.35Six levels, unweightedlinear regression299.87 mAU·s24.00 µg/mLcalibrated range, 1.00 to 50.00 µg/mLBack-calculated standard (% of nominal)9810010201020304050Erinacine A concentration (µg/mL)0100200300400500600700Peak area at 340 nm (mAU·s)Area = 12.48·c + 0.35Six levels, unweightedlinear regression299.87 mAU·s24.00 µg/mLcalibrated rangeBack-calculated standard (% of nominal)9810010201020304050Erinacine A concentration (µg/mL)
Readout
Concentration in the vialc = (299.87 − 0.35) ÷ 12.48 = 24.00 µg/mL
Erinacine A, dry weightw = 24.00 µg/mL × 4 × 10.00 mL ÷ 48.00 mg = 20.0 mg/g, dry weight

Erinacine A, reported20.0mg/g, dry weightU = ±0.8 mg/g (k = 2)

1.2 Mycotoxin analysis

Technique
UPLC after clean-up; detection mode stated on the report
Principle
The ground, mixed sample is extracted with an aqueous organic solvent. The extract is cleaned up on an immunoaffinity column, where an antibody binds the toxin while the matrix is washed away, or on a solid-phase column, and is then separated by reversed-phase liquid chromatography. Aflatoxins and ochratoxin A are commonly detected by fluorescence; deoxynivalenol and patulin by UV absorbance. Each toxin is quantified against a calibration from a reference standard; the detection mode and the limit of quantitation are stated on the report.
Determined
  • Aflatoxins B1, B2, G1 and G2 (individual and total)
  • Ochratoxin A
  • Deoxynivalenol
  • Zearalenone
  • Patulin (apple products)
  • The toxins covered are confirmed on the quote
Reported as
µg/kg of each toxin, as received; total aflatoxins as the sum of B1, B2, G1 and G2
Controls
  • Method blank
  • Calibration from toxin reference standards
  • Spiked sample for recovery
  • Check standard within the run
  • Reference material or quality-control sample where one is available
Sample condition
Mycotoxins are unevenly distributed, so the sample must represent the lot. Ship dry, sealed and protected from light; keep cool so that mold does not grow in transit.
Reading the result
Mycotoxins occur in hot spots, so a result describes the sample received and not the lot; a mold count does not measure mycotoxins, and the absence of visible mold does not show that they are absent.
Reference basis
  • AOAC Official Method 2005.08Aflatoxins in Corn, Raw Peanuts, and Peanut Butter: Liquid Chromatography with Post-Column Photochemical Derivatization
  • AOAC Official Method 2008.02Aflatoxins B1, B2, G1, and G2 and Ochratoxin A in Ginseng and Ginger: Multitoxin Immunoaffinity Column Cleanup and Liquid Chromatographic Quantitation
  • ISO 16050:2003Foodstuffs — Determination of aflatoxin B1, and the total content of aflatoxins B1, B2, G1 and G2 in cereals, nuts and derived products — High-performance liquid chromatographic method
  • EN 15891:2010Foodstuffs — Determination of deoxynivalenol in cereals, cereal products and cereal based foods for infants and young children — HPLC method with immunoaffinity column cleanup and UV detection
Product areas
  • Food and nutritionalCereals, flours and cereal-based foods; Nuts, nut butters and seeds; Spices and dried herbs; Dried fruit; Coffee and cocoa; Botanical and mushroom powders; Apple juice and apple products
  • AgriculturalMaize, wheat, barley and other grains; Oilseeds and oilseed meals; Animal feed and feed ingredients; Grain spawn and grain-based substrates
  • Pharmaceutical-relatedBotanical raw materials; Herbal extracts; Dietary supplement ingredients

1.3 Vitamin analysis

Technique
UPLC-PDA
Principle
Vitamins are released from the matrix before chromatography. Water-soluble vitamins are extracted in dilute acid, with enzymatic hydrolysis where bound forms must be freed; ascorbic acid is extracted in an acid that protects it from oxidation. Vitamins A, D and E are saponified, which breaks down the fat and frees the alcohol forms, and extracted into an organic solvent; vitamin K does not tolerate alkali and is extracted without saponification. After reversed-phase UPLC, each vitamin is identified by retention time and UV spectrum and quantified against its own reference standard.
Determined
  • Water-soluble: thiamine (B1), riboflavin (B2), niacin and niacinamide (B3), pantothenic acid (B5), pyridoxine (B6), folic acid (B9), ascorbic acid (C)
  • Fat-soluble: vitamin A as retinol or retinyl esters, vitamin E as tocopherols or tocopheryl acetate; vitamins D and K at the levels found in supplements and premixes
  • The vitamins and matrices covered are confirmed on the quote
Reported as
mg/100 g or µg/100 g of each vitamin, as received, or per serving when the client supplies the serving size; the chemical form measured is stated
Controls
  • Method blank
  • Calibration from reference standards of known purity
  • Spiked sample for recovery
  • Check standard within the run
  • Preparation under reduced light, with an antioxidant where the method requires one
  • Reference material where one is available
Sample condition
Protect from light, heat and air. Ship in the original sealed container where possible, and ship liquids and fresh products chilled. Vitamins A and C oxidize after a container is opened.
Reading the result
UV detection quantifies vitamins at the levels found in fortified products, supplements and premixes; vitamins present at very low natural levels, such as B12, D, K and folate in unfortified foods, may be below what it can quantify.
Reference basis
  • EN 12823-1:2014Foodstuffs — Determination of vitamin A by high performance liquid chromatography — Part 1: Measurement of all-E-retinol and 13-Z-retinol
  • EN 12822:2014Foodstuffs — Determination of vitamin E by high performance liquid chromatography — Measurement of α-, β-, γ- and δ-tocopherol
  • ISO 20635:2018Infant formula and adult nutritionals — Determination of vitamin C by (ultra) high performance liquid chromatography with ultraviolet detection ((U)HPLC-UV)
Product areas
  • Food and nutritionalFortified foods and beverages; Vitamin premixes; Nutritional powders and meal replacements; Dietary supplements: tablets, capsules, gummies and liquids; Juices and fruit products (vitamin C)
  • AgriculturalFeed premixes; Fortified animal feeds; Fruit and vegetable produce (vitamin C)
  • Pharmaceutical-relatedMultivitamin tablets and capsules; Vitamin raw materials; Nutraceutical blends; Softgels and oil-based formulations

1.4 Volatile compounds

Technique
GC-FID/MS
Principle
Volatile compounds are introduced by headspace sampling or by liquid injection of a solvent extract or diluted oil, and separated on a capillary column under a temperature program. Mass spectrometry identifies each peak by comparing its spectrum with a reference library and its retention index with published values or a reference standard. Flame-ionization detection gives the quantitative signal, calibrated against reference standards, with an internal standard where the method uses one.
Determined
  • Aroma and flavor volatiles
  • Terpenes and terpenoids
  • Essential-oil components
  • Fermentation volatiles: ethanol, higher alcohols, esters and aldehydes
  • Volatile profile of a product or lot
Reported as
mg/kg or mg/L of each compound against reference standards; relative peak area (%) where no standard is used
Controls
  • Solvent blank or empty-vial headspace blank
  • Calibration from reference standards, with an internal standard where used
  • n-Alkane series for retention indices
  • Mass spectrometer tune check
  • Check standard within the run
  • Duplicate preparation where the method specifies one
Sample condition
Ship in a tightly closed, well-filled container; glass with a lined cap for oils and liquids. Keep cool. Do not transfer between containers: volatiles are lost each time a container is opened.
Reading the result
Relative peak-area percent is not a concentration, because detector response differs between compounds and anything that is not volatile or does not elute is not counted; a library match without a reference standard is a tentative identification.
Reference basis
  • ISO 7609:1985Essential oils — Analysis by gas chromatography on capillary columns — General method
  • AOAC Official Method 2016.12Ethanol in Kombucha Products: Headspace Gas Chromatography with Flame-Ionization Detection
Product areas
  • Food and nutritionalFlavorings and flavored products; Essential oils and oleoresins; Fermented beverages and foods; Herbs and spices; Botanical extracts; Coffee, tea and cocoa products
  • AgriculturalAromatic and medicinal plants; Hops; Plant extracts, distillates and essential oils; Fermentation broths
  • Pharmaceutical-relatedEssential oils used as ingredients; Botanical extracts; Nutraceutical oils and softgel fills

1.5 Residual solvents

Technique
Headspace GC-FID/MS
Principle
A weighed portion is dissolved or dispersed in water or a high-boiling solvent such as dimethyl sulfoxide in a sealed vial and heated until the solvents reach equilibrium between the liquid and the gas above it. A portion of the gas phase is injected, so non-volatile matrix does not reach the column. Solvents are separated on a capillary column, quantified by flame ionization against standards of each solvent, and confirmed by mass spectrometry or on a second column of different polarity.
Determined
  • Class 1 solvents (to be avoided), for example benzene and 1,2-dichloroethane
  • Class 2 solvents (to be limited), for example methanol, acetonitrile, hexane, dichloromethane and toluene
  • Class 3 solvents (low toxic potential), for example ethanol, acetone, 2-propanol, ethyl acetate and heptane
  • The solvents covered are confirmed on the quote
Reported as
mg/kg (ppm) of each solvent, as received; compared with the limits the client supplies, or with a named reference at the client's request
Controls
  • Blank vial with diluent only
  • Calibration standards of each solvent in the same diluent
  • System suitability: resolution and signal-to-noise ratio
  • Check standard within the run
  • Spiked sample for recovery
  • Duplicate vials where the method specifies them
Sample condition
Ship in a tightly sealed, well-filled container, kept cool. Do not dry, mill or re-pack the material before shipping, because solvent is lost on handling. State the solvents used in manufacture.
Reading the result
Only the solvents requested and calibrated are reported, so a solvent outside that list is not reported as absent.
Reference basis
  • USP <467>Residual Solvents
  • ICH Q3C(R9)Impurities: Guideline for Residual Solvents
Product areas
  • Food and nutritionalBotanical and mushroom extracts; Flavor extracts and oleoresins; Solvent-extracted oils; Decaffeinated products; Extract-based supplement ingredients
  • AgriculturalSolvent-extracted plant oils and meals; Plant extracts and concentrates; Isolated natural products
  • Pharmaceutical-relatedExcipients and raw materials; Standardized extracts; Isolated natural products; Nutraceutical ingredients; Finished capsules and tablets
Fig. 4Static headspace GC-FID trace of a mixed solvent standard in water on a 624-type column. Peak size is not proportional to concentration from one solvent to the next, because headspace partition and detector response differ; each solvent is quantified against its own calibration. Illustrative data.
020406080100FID response (pA)0123456789Retention time (min)methanol2.60 minethanol3.45 minacetone4.05 min2-propanol4.25 minethyl acetate7.35 min020406080100FID response (pA)0123456789Retention time (min)12345

Static headspace of an aqueous standard · G43 phase (6 % cyanopropylphenyl, 94 % dimethylpolysiloxane; 624-type), 30 m × 0.53 mm, 3.0 µm film · 40 °C for 5 min, then 10 °C/min · flame-ionization detection

PeakSolventtR (min)Area (pA·s)
1methanol2.6017.6
2ethanol3.4556.2
3acetone4.05234.6
42-propanol4.25107.4
5ethyl acetate7.35361.0

1.6 Heavy metal analysis

Technique
ICP-MS
Principle
A weighed, homogenized portion is digested in acid, typically nitric acid in a closed vessel under microwave heating, which destroys the organic matrix and retains volatile elements such as mercury. The diluted digest is nebulized into an argon plasma, where the elements are ionized, and the ions are separated by mass-to-charge ratio. A collision cell, typically filled with helium, reduces polyatomic interferences such as argon chloride on arsenic at mass 75. Each element is quantified against a multi-element calibration, with internal standards correcting for drift and matrix effects.
Determined
  • Arsenic (As), total
  • Cadmium (Cd)
  • Lead (Pb)
  • Mercury (Hg), total
  • Other elements on request
Reported as
mg/kg or µg/kg of each element, on an as-received or dry-weight basis; µg per serving when the client supplies the serving size
Controls
  • Method blank carried through digestion
  • Multi-element calibration with internal standards
  • Matrix reference material with assigned element values
  • Spiked sample for recovery
  • Continuing calibration check and blank check
  • Duplicate digestion
Sample condition
Ship in clean plastic containers or bags and avoid contact with metal tools and containers. Send the material in the form in which it is sold. Keep dry material sealed; ship wet material chilled.
Reading the result
The result is total arsenic and total mercury; it does not distinguish inorganic from organic arsenic, or methylmercury from inorganic mercury, which requires speciation, a different analysis.
Reference basis
  • FDA Elemental Analysis Manual, Section 4.7Inductively Coupled Plasma-Mass Spectrometric Determination of Arsenic, Cadmium, Chromium, Lead, Mercury, and Other Elements in Food Using Microwave Assisted Digestion
  • USP <233>Elemental Impurities—Procedures
  • USP <2232>Elemental Contaminants in Dietary Supplements
  • ICH Q3D(R2)Guideline for Elemental Impurities
Product areas
  • Food and nutritionalBotanical and mushroom powders and extracts; Protein powders, meal replacements and drink powders; Cocoa and chocolate products; Rice and cereal products; Spices; Dietary supplements
  • AgriculturalGrains and pulses; Leafy and root crops; Animal feed and feed ingredients; Dried herbs and plant material; Mushroom fruiting bodies and mycelium
  • Pharmaceutical-relatedDietary supplement ingredients; Botanical raw materials; Botanical extracts; Excipients and mineral ingredients; Capsules, tablets and powders
Fig. 5ICP-MS readout for one acid digest of a plant powder, helium collision mode. Each analyte signal is divided by the signal of an internal standard of similar mass before it is read against the calibration. Lead is measured as the sum of its three main isotopes because their natural proportions vary. Arsenic and mercury are totals. Illustrative data.
102103104105106Net signal (counts per second)200 00074Ge8 00075As400 000103Rh4 800111Cd300 000193Ir300201Hg150 000206Pb + 207Pb+ 208Pb500 000209Bianalyteinternal standard, added at a fixed concentration to every solutionanalyteinternal standard, added at a fixedconcentration to every solutioncps74Ge200 00075As8 000103Rh400 000111Cd4 800193Ir300 000201Hg300206+207+208Pb150 000209Bi500 000102103104105106Net signal (counts per second)
ElementIsotope measuredInternal standardRatio (analyte ÷ internal standard)Calibration slope (ratio per µg/L)Digest (µg/L)Sample (mg/kg)
As7574Ge0.04000.02002.000.40
Cd111103Rh0.01200.01500.800.16
Hg201193Ir0.00100.01000.100.020
Pb206 + 207 + 208209Bi0.30000.20001.500.30
AsCdHgPb
Isotope measured75111201206 + 207 + 208
Internal standard74Ge103Rh193Ir209Bi
Ratio (analyte ÷ internal standard)0.04000.01200.00100.3000
Calibration slope (ratio per µg/L)0.02000.01500.01000.2000
Digest (µg/L)2.000.800.101.50
Sample (mg/kg)0.400.160.0200.30

Sample (mg/kg) = digest (µg/L) × 0.1000 L ÷ 0.500 g. The test portion and final volume are those of this illustration, not a sample requirement.

Additional service

Method development and validation

Technique
UPLC-PDA, GC-FID/MS, ICP-MS
Principle
Where no existing method covers an analyte or matrix, a procedure is developed: extraction or digestion, separation, detection and calibration are selected and tested on the client's material. The procedure is then validated against a written protocol with predefined acceptance criteria. A published compendial method is not validated again; its suitability for the client's material is verified.
Determined
  • Specificity or selectivity
  • Range: response (calibration model) and lower range limits (detection and quantitation limits)
  • Accuracy
  • Precision: repeatability and intermediate precision
  • Robustness, evaluated during development
Reported as
Validation or verification report: protocol, results, statistics, acceptance criteria and a conclusion for each characteristic
Controls
  • Written protocol agreed before the work starts
  • Predefined acceptance criteria
  • Reference standards of documented purity
  • System suitability in every run
  • Deviations recorded and assessed in the report
Sample condition
Representative material from more than one lot where available, a blank or placebo matrix if one exists, and the reference standard or its source. Details are agreed in the protocol.
Reading the result
A validation applies to the analyte, matrix and range stated in the report, and a validation report is not a regulatory approval of the method.
Reference basis
  • ICH Q2(R2)Validation of Analytical Procedures
  • USP <1226>Verification of Compendial Procedures
  • AOAC Official Methods of Analysis, Appendix KGuidelines for Dietary Supplements and Botanicals
Product areas
  • Food and nutritionalNew ingredient or bioactive compound with no published method; Existing method applied to a new food matrix; Label-claim compounds in finished products
  • AgriculturalPlant, fungal or microbial metabolites; Fermentation products; New crop or feed matrices
  • Pharmaceutical-relatedMarker compounds in botanical extracts; New active ingredients and research formulations; Nutraceutical actives in finished dosage forms; Verification of a compendial method on a client's material

Questions

Questions about specialized analytical testing
QuestionAnswer
Can you measure a compound that is not listed here?If the compound absorbs ultraviolet or visible light, or is volatile, and a reference standard can be obtained, a method can usually be set up. This is quoted as method development and validation. A compound without a chromophore needs another detector or derivatization; whether that is possible is confirmed on the quote.
What is the lowest level you can report?The limit of quantitation depends on the analyte, the matrix and the test portion. It is established for each method and stated on the report. A result below it is reported as less than that value, not as zero.
Does a heavy-metal result tell me whether my product meets a limit?The report gives the measured concentration; measurement uncertainty is reported on request, and whenever it affects a statement of conformity. We compare the result with the specification or limit you supply, or with a named reference at your request, and state the decision rule used. We do not choose the limit.
Is total arsenic the same as inorganic arsenic?No. ICP-MS after acid digestion measures total arsenic, the sum of all its chemical forms. Inorganic arsenic is one fraction of that total and can only be measured after the forms are separated, which is called speciation. The same applies to total mercury and methylmercury.
Why are some volatile results given in area percent and others in mg/kg?A concentration in mg/kg requires a reference standard of that compound. Without one, the peak is reported as a share of the total detected peak area. Area percent shows relative composition and is not a concentration.

Request these tests

Tick tests on this page or in the catalog. The quote confirms the sample amount for each test, the turnaround and the price.

Request a quoteSubmit samples