Physicochemical analysis
Physicochemical tests measure bulk properties of a product: pH, bulk and tapped density, moisture, solubility and ash. Product developers order them to set and check specifications, to calculate dry-weight results and to plan formulation, capsule filling and packaging.
Tests in this category
| Select | No. | Test | Technique | Reported as |
|---|---|---|---|---|
| 3.1 | pH | Potentiometry (glass electrode) | pH with the measurement temperature | |
| 3.2 | Bulk density | Graduated cylinder (bulk, tapped) | g/mL, bulk and tapped density | |
| 3.3 | Moisture content | Loss on drying | % w/w, as received | |
| 3.4 | Solubility | Shake-flask equilibration | mg/mL, a descriptive term, or % w/w | |
| 3.5 | Ash content | Gravimetry (muffle furnace) | % w/w |
Reference basis is the published method a procedure is built on. The method used, and any modification, is stated on the report. Sample amount, turnaround and price are confirmed on the quote.
Overview
Results in this category are defined by the test conditions. Loss on drying depends on temperature and time. Tapped density depends on the number of taps and the drop height. The pH of a powder depends on the concentration of the dispersion. Solubility depends on solvent, temperature and equilibration time. The report states these conditions with each result, because a number cannot be compared with a specification without them.
Four of the five results come from weighings: loss on drying is the mass lost, ash is the mass left after incineration, bulk density is mass divided by volume, and a gravimetric solubility is the mass of dissolved solid. They depend on the balance, on temperature control and on drying or igniting to constant mass. pH is the exception: a potential measured against standard buffer solutions.
Moisture content links this category to the others. A result on a dry-weight basis is the as-received result divided by the dry-matter fraction, so the moisture of the same sample is needed. Moisture content is not water activity, which is a different property and is not measured by these tests.
For powders, bulk density, tapped density and solubility describe how a material behaves in manufacture and use: how much fills a capsule or a pouch, how it flows, and how much dissolves in a stated solvent. These are properties of the lot as supplied. Particle size, moisture and handling change them, so the report states whether the sample was tested as received or after sieving or drying.
3.1 pH
- Technique
- Potentiometry (glass electrode)
- Principle
- pH is measured potentiometrically with a glass electrode and a reference electrode. For an ideal electrode the potential between them changes by 59.16 mV per pH unit at 25 °C. The meter is calibrated on standard buffer solutions that bracket the expected sample pH and is checked with a further buffer; the temperature is recorded and the slope is compensated for it. Liquids are measured directly, and powders and other solids as a dispersion in water at a stated concentration.
- Determined
- pH of liquids, measured directly
- pH of powders and other solids, measured as a dispersion in water at a stated concentration (for example 1 % or 10 % w/v)
- Apparent pH of samples that are only partly aqueous, labeled as such
- Reported as
- pH with the measurement temperature; for solids, the concentration of the dispersion (% w/v) is reported with the result
- Controls
- Calibration on standard buffer solutions that bracket the sample pH
- Electrode slope and offset checked at each calibration
- Verification buffer, not used for calibration, read before samples
- Temperature of buffers and samples recorded
- Buffer read again at the end of the batch to check drift
- Duplicate readings on separate test portions
- Sample condition
- Send liquids in full, tightly closed containers; chill perishable and fermenting products. Send powders sealed against moisture. State the dispersion concentration your specification requires, if it names one.
- Reading the result
- The pH of a dispersion is not a property of the powder alone: it changes with concentration, water quality and standing time, so results at different concentrations are not comparable.
- Reference basis
- USP <791>pH
- 21 CFR 114.90Methodology
- Product areas
- Food and nutritionalBeverages and liquid concentrates; Sauces, dressings and acidified foods; Fermented foods and drinks; Powdered drink mixes (as a dispersion); Mushroom and botanical extracts
- AgriculturalLiquid microbial formulations and inoculants; Fermentation broths; Plant and mushroom extracts
- Pharmaceutical-relatedOral liquids and syrups; Aqueous solutions of ingredients and excipients; Nutraceutical powders (as a dispersion)
| Buffer pH 4.01 | +176.4 mV |
|---|---|
| Buffer pH 10.01 | −171.6 mV |
| Slope | −58.00 mV per pH unit, 98.0 % of the theoretical −59.16 mV per pH unit |
| Offset, on the line at pH 7.00 | +3.0 mV |
| Verification buffer pH 7.00 | +2.4 mV, reads 7.01 |
| Sample, 10 % w/v dispersion in water | +86.5 mV |
Sample pH5.56pH at 25 °C
Calibration line: E = 408.98 − 58.00 × pH (E in mV)
Slope = (−171.6 − 176.4) / (10.01 − 4.01) = −348.0 / 6.00 = −58.00 mV per pH unit; 58.00 / 59.16 × 100 = 98.0 %
Verification: (408.98 − 2.4) / 58.00 = 406.58 / 58.00 = 7.01
Sample: (408.98 − 86.5) / 58.00 = 322.48 / 58.00 = 5.56
Theoretical slope at 25 °C: 2.3026 × R × T / F = 0.05916 V, with R = 8.314 J/(mol·K), T = 298.15 K and F = 96 485 C/mol.
3.2 Bulk density
- Technique
- Graduated cylinder (bulk and tapped)
- Principle
- Weighed powder is passed into a dry graduated cylinder without compaction, and the unsettled volume is read; bulk density is the mass divided by this volume. The cylinder is tapped mechanically from a fixed height and the volume is read after set numbers of taps, until successive readings agree within the method's tolerance. Tapped density is the mass divided by the final volume. The compressibility index and the Hausner ratio are calculated from the two volumes.
- Determined
- Bulk density (poured, untapped)
- Tapped density
- Compressibility index = 100 × (V0 − Vf) / V0
- Hausner ratio = V0 / Vf
- Reported as
- g/mL for bulk density and tapped density; compressibility index (%) and Hausner ratio where requested; the number of taps and the drop height are stated
- Controls
- Balance checked with calibrated weights
- Graduated cylinder of stated capacity and graduation
- Tap count and drop height of the tapping apparatus verified
- Volume read after each tapping stage until successive readings agree
- Replicate determinations on separate portions
- Sample condition recorded (as received, or sieved to break up agglomerates)
- Sample condition
- Send powder in a rigid, sealed container that protects it from moisture and compaction. Do not grind or sieve the sample before sending unless your specification requires it. Sample amount is confirmed on the quote.
- Reading the result
- Bulk and tapped density describe the powder in the state tested and are not material constants, and the compressibility index and the Hausner ratio indicate flow behavior without measuring flow rate.
- Reference basis
- USP <616>Bulk Density and Tapped Density of Powders
- USP <1174>Powder Flow
- Product areas
- Food and nutritionalProtein and meal-replacement powders; Powdered drink mixes; Flours and starches; Spice and seasoning powders; Mushroom and botanical powders
- AgriculturalMilled grains and meals; Dried, milled plant material; Dried mushroom powders; Powdered and granular microbial formulations
- Pharmaceutical-relatedCapsule and tablet powder blends; Excipients and carriers; Dry extract powders; Granules
| Taps | Volume, mL | Density, g/mL |
|---|---|---|
| 0 | 75 | 0.400 |
| 10 | 71 | 0.423 |
| 500 | 61 | 0.492 |
| 1250 | 60 | 0.500 |
Density = 30.00 g / volume. The readings at 500 and 1250 taps differ by 1 mL, within the 1 mL allowed for a 100 mL cylinder (USP <616>), so tapping stops and 60 mL is the final volume.
The mass and the cylinder size are example values chosen for the arithmetic and are not sample requirements.
3.3 Moisture content
- Technique
- Loss on drying
- Principle
- A weighed test portion is dried in an oven at a stated temperature, commonly 105 °C, for a fixed time or to constant mass, and is cooled in a desiccator before each weighing. The loss includes water and any other substance volatile at that temperature.
- Determined
- Loss on drying: water and other matter volatile under the drying conditions
- Dry matter (100 % minus loss on drying), the basis for dry-weight results
- Reported as
- % w/w of the sample as received; the drying temperature and the end-point criterion are stated on the report
- Controls
- Balance checked with calibrated weights
- Oven temperature verified with a calibrated thermometer
- Drying to constant mass, or for the fixed time the method states
- Control material of known moisture content with each batch
- Duplicate test portions
- Sample condition
- Send in airtight, moisture-tight containers filled to leave little headspace. Do not open, dry or repack the sample before sending. Keep fresh or high-moisture material chilled and sealed.
- Reading the result
- Loss on drying counts volatile oils, residual solvents and decomposition losses as well as water, and may not release tightly bound water. Karl Fischer titration (USP <921>, Method I) is a different measurement, of water specifically, that a specification may call for; the test offered here is loss on drying.
- Reference basis
- USP <731>Loss on Drying
- AOAC 925.10Solids (Total) and Loss on Drying (Moisture) in Flour: Air Oven Method
- Product areas
- Food and nutritionalPowdered foods, drink mixes and premixes; Flours, cereals and grain products; Dried fruit, vegetable and mushroom powders; Botanical and mushroom powders and extracts; Protein powders and bars; Nuts, seeds and dried fruit; Herbs, spices and teas
- AgriculturalGrains, pulses and oilseeds; Dried mushrooms and mycelial biomass; Dried herbs, roots and plant material; Animal feed and feed ingredients; Dry microbial formulations
- Pharmaceutical-relatedDry extract powders; Botanical raw materials; Capsule and tablet powder blends; Excipients; Nutraceutical ingredients
| Mass at 0 h | 2.0000 g |
|---|---|
| Constant mass, 5 h | 1.9200 g |
| Loss | 0.0800 g |
| Change, 4 h to 5 h | 0.4 mg (0.20 mg/g), not more than 0.50 mg/g |
Loss on drying4.00% w/w
Loss on drying = (2.0000 − 1.9200) / 2.0000 × 100 = 0.0800 / 2.0000 × 100 = 4.00 % w/w
Dry matter = 100 − 4.00 = 96.00 % w/w
Dry-weight basis = result as received / 0.960. Simulated erinacine A run: 19.2 mg/g as received / 0.960 = 20.0 mg/g dry weight
Constant mass (USP General Notices 6.40.20): two consecutive weighings, the second after a further hour of drying, differ by no more than 0.50 mg per g of test portion, which is 1.0 mg for 2.0000 g.
The mass of the test portion is an example value chosen for the arithmetic and is not a sample requirement.
3.4 Solubility
- Technique
- Shake-flask equilibration; gravimetric or UPLC-PDA
- Principle
- Quantitative solubility: excess solid is agitated in a stated solvent at a stated temperature until the dissolved concentration is constant. Undissolved solid is filtered or centrifuged off, and the dissolved amount is measured by evaporating a known volume to dryness and weighing, or by UPLC-PDA for a named compound. Descriptive solubility assigns a pharmacopeial term from the volume of solvent that dissolves one part of solute. For extract powders, the water-soluble fraction is the percentage of the powder that dissolves at a stated powder-to-water ratio.
- Determined
- Quantitative solubility in a stated solvent at a stated temperature
- Descriptive solubility term: very soluble, freely soluble, soluble, sparingly soluble, slightly soluble, very slightly soluble, practically insoluble
- Water-soluble fraction of an extract or powder
- Insoluble residue, weighed after drying
- Reported as
- mg/mL (quantitative), a descriptive term, or % w/w (water-soluble fraction); solvent, temperature and equilibration time are stated with every result
- Controls
- Temperature controlled and recorded during equilibration
- Undissolved solid still present at the end of equilibration
- Equilibrium checked by sampling at more than one time point
- Solvent blank carried through filtration and evaporation
- Calibration and check standard for UPLC-PDA quantification
- Duplicate determinations
- Sample condition
- Send solids sealed against moisture at ambient temperature. State the solvent, the temperature and, for UPLC-PDA quantification, the compound to be measured. Tell us if the material is light-sensitive or hygroscopic.
- Reading the result
- Solubility states how much dissolves at equilibrium, not how fast, and for a mixture such as an extract the result is the soluble fraction under the stated conditions, not the solubility of any single compound.
- Reference basis
- USP General Notices 5.30Description and Solubility
- USP <1236>Solubility Measurements
- OECD Test Guideline 105Water Solubility
- Product areas
- Food and nutritionalInstant drink powders; Protein and meal-replacement powders; Mushroom and botanical extract powders; Sweeteners, fibers and hydrocolloids; Flavor and color ingredients
- AgriculturalDried, milled plant material (water-soluble fraction); Plant and mushroom extracts; Seaweed and algal extracts
- Pharmaceutical-relatedActive ingredients; Excipients; Dry extract powders; Nutraceutical ingredients
3.5 Ash content
- Technique
- Gravimetry (muffle furnace)
- Principle
- A weighed test portion is charred gently in a tared crucible and then incinerated in a muffle furnace, usually at 550 °C to 600 °C, until the residue is free of carbon and its mass is constant. Organic matter burns off, and the residue is the total ash: the mineral content as oxides, carbonates, phosphates and other salts. For acid-insoluble ash, the total ash is boiled with dilute hydrochloric acid, and the insoluble matter is collected on ashless filter paper, washed, ignited and weighed.
- Determined
- Total ash
- Acid-insoluble ash (on request): the part of the total ash that does not dissolve in dilute hydrochloric acid, mainly silica from sand and soil
- Reported as
- % w/w, as received or on a dry-weight basis; the ignition temperature and the basis are stated on the report
- Controls
- Crucibles ignited, cooled in a desiccator and tared before use
- Furnace temperature verified
- Ignition repeated to constant mass
- Control material of known ash content with each batch
- Duplicate test portions
- Sample condition
- Send dry material in clean, sealed containers. Do not wash or sieve raw botanical material before sending, because adhering soil is part of what acid-insoluble ash measures. Chill fresh material.
- Reading the result
- Total ash is the sum of the mineral residue and does not identify elements, some of which are partly lost at furnace temperature; individual elements are determined by ICP-MS.
- Reference basis
- AOAC 923.03Ash of Flour: Direct Method
- AOAC 942.05Ash of Animal Feed
- AOAC 941.12Ash of Spices: Gravimetric Methods
- Product areas
- Food and nutritionalFlours, cereals and grain products; Herbs, spices and teas; Mushroom and botanical powders; Protein powders, meal replacements and drink powders; Dried fruit and vegetable powders
- AgriculturalGrains, pulses and oilseeds; Forage, animal feed and feed ingredients; Dried herbs, roots and leaves; Dried mushrooms and mycelial biomass; Plant biomass
- Pharmaceutical-relatedBotanical and mushroom extracts; Dried botanical raw materials; Nutraceutical powder blends; Excipients of plant origin
Questions
| Question | Answer |
|---|---|
| What is the difference between moisture content and water activity? | Moisture content is the amount of water, or of volatile matter, in the sample as % w/w. Water activity is the ratio of the water vapor pressure over the sample to that of pure water at the same temperature. Two products with the same moisture content can have different water activities. Water activity is not among the tests listed here. |
| Is loss on drying the same as water content? | Not always. Loss on drying reports everything volatile at the drying temperature, so volatile oils and residual solvents are counted with the water. It is the usual basis for dry-weight results. If your specification names a method that measures water specifically, state it when you request a quote. |
| At what concentration is the pH of a powder measured? | At the concentration your specification states. Where it states none, we measure a dispersion in water at a concentration confirmed on the quote, for example 1 % or 10 % w/v. The concentration and the temperature are reported with the pH, because results at different concentrations are not comparable. |
| Why do formulators ask for both bulk density and tapped density? | Bulk density gives the volume a powder occupies as filled; tapped density gives the volume after it settles in handling and transport. Both are used to choose capsule size, fill weight, container volume and headspace. The Hausner ratio and the compressibility index, calculated from them, indicate how readily the powder flows. |
| Is total ash the same as residue on ignition or sulfated ash? | No. Total ash is the residue after incineration in air. Residue on ignition, also called sulfated ash, is obtained by igniting the sample with sulfuric acid, so the residue is weighed as sulfates and the two results are not interchangeable. State which test your specification names. Acid-insoluble ash is a further test on the total ash. |
Request these tests
Tick tests on this page or in the catalog. The quote confirms the sample amount for each test, the turnaround and the price.