Testing services

The catalog lists every test in the six categories. Method development and validation is listed after them as an additional service. The catalog can be filtered by product area.

Each row gives the test, the technique, what is reported and the product areas it applies to. The principle, the reference basis and the controls for each test are on its category page. Tick the tests you need; the selection is carried into the quote request on the Contact page.

Product area

28 of 28 rows

Tests

1Specialized analytical testing

Specialized analytical testing
SelectNo.TestTechniqueReported asProduct areas
1.1Metabolites and bioactive compoundsUPLC-PDAmg/g or % w/wAll three
1.2Mycotoxin analysisUPLC after clean-upµg/kg, as receivedAll three
1.3Vitamin analysisUPLC-PDAmg/100 g or µg/100 gAll three
1.4Volatile compoundsGC-FID/MSmg/kg or mg/LAll three
1.5Residual solventsHeadspace GC-FID/MSmg/kg (ppm)All three
1.6Heavy metal analysisICP-MSmg/kg or µg/kgAll three

2Enzymatic and biochemical assays

Enzymatic and biochemical assays
SelectNo.TestTechniqueReported asProduct areas
2.1Total polysaccharidesPhenol-sulfuric acid colorimetry% w/w as glucose equivalentsAll three
2.2Beta-glucanEnzymatic assay% w/w (g/100 g)All three
2.3Total carbohydratesPhenol-sulfuric acid colorimetry% w/w as glucose equivalentsAll three
2.4Total protein contentKjeldahl or Dumas nitrogen% w/w crude protein as N × factorAll three

3Physicochemical analysis

Physicochemical analysis
SelectNo.TestTechniqueReported asProduct areas
3.1pHPotentiometry (glass electrode)pH with the measurement temperatureAll three
3.2Bulk densityGraduated cylinder (bulk, tapped)g/mL, bulk and tapped densityAll three
3.3Moisture contentLoss on drying% w/w, as receivedAll three
3.4SolubilityShake-flask equilibrationmg/mL, a descriptive term, or % w/wAll three
3.5Ash contentGravimetry (muffle furnace)% w/wAll three

4Microbiological testing

Microbiological testing
SelectNo.TestTechniqueReported asProduct areas
4.1Total viable count and total bacterial countPlate countCFU/g or CFU/mLAll three
4.2Total fungal count and yeast and mold countPlate countCFU/g or CFU/mLAll three
4.3Coliforms and E. coliPlate count or MPNCFU/g or MPN/g for countsAll three
4.4Salmonella detectionEnrichment cultureDetected or not detectedAll three
4.5Antibiotic resistance testingDisk diffusion, microdilutionZone diameter in mm or MIC in µg/mLAll three

5Molecular identification

Molecular identification
SelectNo.TestTechniqueReported asProduct areas
5.1Microbial identificationPCR and marker-gene sequencingClosest matches, percent identityAll three
5.2Targeted PCRPCR with target-specific primersDetected or not detectedAll three

6Shelf-life and stability studies

Shelf-life and stability studies
SelectNo.TestTechniqueReported asProduct areas
6.1Food and nutritional productsReal-time and accelerated storageResult for each attribute and time pointFood and nutritional
6.2Pharmaceutical and nutraceutical productsLong-term and accelerated storageResults by batch, condition and time pointPharmaceutical-related
6.3Agricultural productsStorage with time-point testingResult for each attribute and time pointAgricultural
6.4Viability of microbial formulationsViable count over storage timeCFU/g or CFU/mL and log10 CFUAll three
6.5Stability under different storage conditionsStorage at several conditionsResults by condition, pack and time pointAll three

Additional service

Additional service
SelectNo.TestTechniqueReported asProduct areas
Method development and validationUPLC-PDA, GC-FID/MS, ICP-MSValidation or verification reportAll three
Product areas
Food and nutritional products; agricultural products; pharmaceutical-related and nutraceutical products.
Confirmed on the quote
Sample amount, turnaround and price are confirmed on the quote.
Stated on the report
The method used and the limit of quantitation. Measurement uncertainty is reported on request, and whenever it affects a statement of conformity.
Reference basis
Reference basis is the published method a procedure is built on. The method used, and any modification, is stated on the report. Each category page lists the reference basis of its tests.
Reporting against limits
Results are reported against the specification or limit the client supplies, or against a named reference at the client’s request.

Quote request

No tests are selected. Tick tests in the catalog above, or request a quote and describe the product.

Submit samples

Selected tests arrive pre-filled in the quote form. Pricing never depends on results.